Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Braz. j. otorhinolaryngol. (Impr.) ; 86(6): 720-726, Nov.-Dec. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1142596

RESUMO

Abstract Introduction: The increase in the spectral information offered by the sound processing strategy HiRes 120 has led to great expectations for the pediatric population. Due to a shorter duration of auditory deprivation and higher neural plasticity, children could benefit more substantially from the spectral information of this sound processing strategy. Objective: To compare auditory and language skills in Brazilian children with cochlear implants using the HiRes and HiRes 120 sound processing strategies. Methods: Thirty children, aged 1-3 years, with congenital hearing loss, were divided into two groups, according to the signal processing strategy adjusted at the time of the cochlear implant activation. The assessed children were matched according to chronological age and the time of the cochlear implant use. The auditory and language skills were evaluated longitudinally through the Infant-Toddler Meaningful Auditory Integration Scale and Production Infant Scale Evaluation, carried out before surgery, and 3, 6 and 12 months after device implantation. The Mann-Whitney test was applied for the comparison between the two groups with a 5% significance level. Results: The findings indicated development of hearing and language skills in the first year of cochlear implant use; however, there was no statistically significant difference in the evolution of such skills due to the adjusted processing strategy in the activation of the cochlear implant electrodes. Conclusion: The development of auditory and language skills in the assessed children was similar during the entire study period, regardless of which signal processing strategy was used.


Resumo Introdução: O aumento das informações espectrais proporcionado pela estratégia de processamento de sinal HiRes 120 gera expectativas em relação à população pediátrica, uma vez que, devido ao curto período de privação sensorial e da maior plasticidade neural, as crianças poderiam se beneficiar de forma mais substancial das informações espectrais dessa estratégia de processamento de sinal. Objetivo: Comparar as habilidades auditivas e de linguagem em crianças usuárias de implante coclear, com a estratégia de processamento de sinal HiRes e HiRes 120. Método: Trinta crianças de um a três anos e com perda auditiva congênita foram divididas em dois grupos, de acordo com a estratégia de processamento de sinal ajustada no momento da ativação do implante coclear. As crianças avaliadas foram pareadas de acordo com a idade cronológica e o tempo de uso do implante coclear. As habilidades auditivas e de linguagem foram avaliadas, longitudinalmente, por meio do Infant-Toddler Meaningful Auditory Integration Scale e Production Infant Scale Evaluation, antes do implante coclear e com 3, 6 e 12 meses de uso do dispositivo. O teste estatístico de Mann-Whitney foi aplicado para comparar os resultados dos grupos, com nível de significância de 5%. Resultados: Os achados indicaram desenvolvimento das habilidades auditivas e de linguagem no primeiro ano de uso do implante coclear, porém sem diferença estatisticamente significante na evolução de tais habilidades, em função da estratégia de processamento ajustada na ativação dos eletrodos do implante coclear. Conclusão: O desenvolvimento das habilidades auditivas e de linguagem das crianças avaliadas foi semelhante durante o período do presente estudo, independentemente da estratégia de processamento de sinal usada.


Assuntos
Humanos , Lactente , Pré-Escolar , Percepção da Fala , Implantes Cocleares , Implante Coclear , Surdez/cirurgia , Brasil , Idioma , Desenvolvimento da Linguagem
2.
Braz J Otorhinolaryngol ; 86(6): 720-726, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31324459

RESUMO

INTRODUCTION: The increase in the spectral information offered by the sound processing strategy HiRes 120 has led to great expectations for the pediatric population. Due to a shorter duration of auditory deprivation and higher neural plasticity, children could benefit more substantially from the spectral information of this sound processing strategy. OBJECTIVE: To compare auditory and language skills in Brazilian children with cochlear implants using the HiRes and HiRes 120 sound processing strategies. METHODS: Thirty children, aged 1-3 years, with congenital hearing loss, were divided into two groups, according to the signal processing strategy adjusted at the time of the cochlear implant activation. The assessed children were matched according to chronological age and the time of the cochlear implant use. The auditory and language skills were evaluated longitudinally through the Infant-Toddler Meaningful Auditory Integration Scale and Production Infant Scale Evaluation, carried out before surgery, and 3, 6 and 12 months after device implantation. The Mann-Whitney test was applied for the comparison between the two groups with a 5% significance level. RESULTS: The findings indicated development of hearing and language skills in the first year of cochlear implant use; however, there was no statistically significant difference in the evolution of such skills due to the adjusted processing strategy in the activation of the cochlear implant electrodes. CONCLUSION: The development of auditory and language skills in the assessed children was similar during the entire study period, regardless of which signal processing strategy was used.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Percepção da Fala , Brasil , Pré-Escolar , Surdez/cirurgia , Humanos , Lactente , Idioma , Desenvolvimento da Linguagem
3.
Rev. CEFAC ; 16(5): 1419-1425, Sep-Oct/2014. tab, graf
Artigo em Português | LILACS | ID: lil-729923

RESUMO

OBJETIVO: identificar quais são as falhas técnicas mais frequentes dos componentes externos do implante coclear e verificar a influência da idade do usuário e o tempo de uso do dispositivo nestas falhas. MÉTODOS: estudo retrospectivo, por meio da análise de 128 prontuários da Associação dos Deficientes Auditivos, Pais, Amigos e Usuários de Implante Coclear, que apresentaram alguma queixa no funcionamento do componente externo, no período de junho a agosto de 2011. Para análise dos dados foi realizada a análise descritiva dos componentes que apresentaram falha técnica, bem como das variáveis estudadas. Posteriormente, foi aplicada a estatística inferencial por meio do teste Kruskal-Wallis para verificar a influência da idade do paciente e tempo de uso do implante coclear com a falha apresentada, com nível de significância p< 0,05. RESULTADOS: os componentes que apresentaram mais falhas foram: antena externa (29,7%), seguida do compartimento de bateria (23,4%), processador de fala (14,10%), microfone (10,90%), cabos de transmissão (9,40%), controlador (6,30%), baterias (5,50%) e carregador de baterias (0,80%). Não foi verificada influência do tempo de uso do implante coclear e a idade cronológica do paciente em relação às falhas apresentadas no presente estudo. CONCLUSÃO: os achados obtidos a partir do presente estudo podem auxiliar os profissionais da área na orientação sobre a manutenção destes componentes, mas as tendências aqui apresentadas não podem ser generalizadas para todo território nacional, pois estas foram analisadas em um número limitado de casos. .


PURPOSE: to identify what are the most frequent technical flaws of the external components of the cochlear implant and verify the influence of age and the time of use of the device in these failures. METHODS: retrospective study. It was analyzed 128 medical records of the Association of Deaf Parents, Friends and Cochlear Implant Users, which presented a complaint in the functioning of the external component for the period from June to August 2011. For analysis of data was carried out the descriptive analysis of failed components, as well as the variables studied. It was applied to an inferential statistics through the Kruskal-Wallis test to analyze the influence of patient’s age and time of use of the cochlear implant with failure, with significance level p <0.05. RESULTS: the components that were more failure was the external antenna (29,7%), followed by the battery compartment (23,4%), speech processor (14,10%), microphone (10,90%), transmission cables (9,40%), controller (6,30%), batteries (5,50) and battery charge (0,80%). Has not been verified influence of time of use of the cochlear implant and the chronological age of the patient in relation to failures presented in this study. CONCLUSION: the findings obtained from this study can assist professionals in guidance on the maintenance of these components, but the trends presented here cannot be generalized to the entire national territory, as these were analyzed in a limited number of cases. .

4.
Rev. CEFAC ; 16(1): 55-64, 03/2014. tab, graf
Artigo em Português | LILACS | ID: lil-707236

RESUMO

Objetivo : investigar quais as principais falhas técnicas dos aparelhos de amplificação sonora individual fornecidos nos serviços do Sistema Único de Saúde.Métodos : foram analisadas as falhas técnicas dos aparelhos de amplificação sonora individual em cinco serviços credenciados pelo Ministério da Saúde, entre janeiro e maio de 2009, utilizando-se estatística descritiva.Resultados : as principais falhas técnicas encontradas nos dispositivos foram 37.44% de falha no amplificador, seguidas de 25.59% de falha no microfone. Os aparelhos de amplificação sonora individual retroauriculares e de categoria tecnológica A são os que apresentam maior ocorrência de falha técnica. O tempo de vida útil dos aparelhos de amplificação sonora individual sem apresentar defeito foi de 22 meses, em média. Na maior parte da população estudada, o custo para o conserto destes dispositivos foi entre R$500,00 e R$ 1000,00. Dos casos analisados, 51.82% entraram em contato com o serviço de saúde auditiva para buscar atendimento e verificar o problema e em 61% dos casos os aparelhos de amplificação sonora individual ainda estavam no prazo de garantia e foram consertados pela assistência técnica sem custo adicional para o paciente.Conclusão : a principal falha encontrada refere-se à falha do amplificador. Os AASI retroauricular e de categoria tecnológica A são os que apresentam maior ocorrência de falha técnica.


Purpose : to investigate about repair issues of hearing aids at National Health System.Methods : it was analyzed hearing aids technical failures whose patients had showed complaints concerning the device on five different services considering the period from January to May 2009, analyzed by descriptive statistic.Results : the main technical failures found were: 37.44% of failures on amplifier, 25.59% of failures on microphone. Related to the device’s technological sort and category it’s verified that the behind the ear hearing aids and of category A presented higher technical failure incidence. It’s also observable that the devices presented utility life of 22 months on average before presenting any technical failure. In the majority of the population studied, the cost for the repair of these devices was between R $ 500,00 and $ 1000.00. From the perception of hearing aids failure by the patient, 51.82% contacted the service seeking for care and 61% of analyzed hearing aids were still on guarantee term and they were fixed by technical assistance without additional cost to patient.Conclusion : the main technical failure found was failures on amplifier. The behind the ear hearing aids and of category A presented higher technical failure incidence.

5.
CoDAS ; 25(6): 584-587, 25/1jan. 2013. tab
Artigo em Inglês | LILACS | ID: lil-699841

RESUMO

Purpose: To perform a systematic review of the literature on questionnaires to assess the benefits of using hearing aids in children. Methods: A literature search was conducted in the data-bases Web of Science and Virtual Health Library (BIREME). The selection criteria included: title consistent with the purpose of this review; participants necessarily being children using hearing aids; and questionnaires to assess the benefits and satisfaction. Results: More evidence was found in studies that used the scale Parent's Evaluation of Aural/Oral Performance of Children (PEACH), making it possibly the most consistent scale on the subjective evaluation of the use of amplification in children. Conclusion: There is a paucity of studies with this approach; however, the results showed the importance of researches in this area, which turns the subject into an important field of research. .


OBJETIVO: Realizar revisão sistemática da literatura sobre questionários que avaliem benefícios do uso de aparelhos de amplificação sonora individuais em crianças. MÉTODOS: Foi realizada uma revisão sistemática da literatura nas bases de dados Web of Science e no portal Biblioteca Virtual em Saúde (BIREME). Os critérios adotados incluíram título condizente com a proposta deste estudo, casuística necessariamente englobando crianças usuárias de aparelhos de amplificação sonora individuais, uso de questionários e os resultados dos questionários de avaliação do benefício e satisfação. RESULTADOS: Maior evidência foi encontrada nos estudos que utilizaram a escala Parent's Evaluation of Aural/Oral Performance of Children (PEACH), tornando-a possivelmente a escala mais consistente na avaliação subjetiva do uso de amplificação em crianças CONCLUSÃO: São escassos estudos com esse enfoque; contudo, os resultados obtidos demonstraram a importância de serem realizadas pesquisas nessa área, tornando esse um importante campo de investigação. .


Assuntos
Criança , Humanos , Correção de Deficiência Auditiva , Auxiliares de Audição , Inquéritos e Questionários , Prática Clínica Baseada em Evidências , Transtornos da Audição/terapia , Pais , Satisfação Pessoal
6.
Braz J Otorhinolaryngol ; 79(5): 629-35, 2013.
Artigo em Inglês, Português | MEDLINE | ID: mdl-24141681

RESUMO

UNLABELLED: The signal processing strategy is a parameter that may influence the auditory performance of cochlear implant and is important to optimize this parameter to provide better speech perception, especially in difficult listening situations. OBJECTIVE: To evaluate the individual's auditory performance using two different signal processing strategy. METHOD: Prospective study with 11 prelingually deafened children with open-set speech recognition. A within-subjects design was used to compare performance with standard HiRes and HiRes 120 in three different moments. During test sessions, subject's performance was evaluated by warble-tone sound-field thresholds, speech perception evaluation, in quiet and in noise. RESULTS: In the silence, children S1, S4, S5, S7 showed better performance with the HiRes 120 strategy and children S2, S9, S11 showed better performance with the HiRes strategy. In the noise was also observed that some children performed better using the HiRes 120 strategy and other with HiRes. CONCLUSION: Not all children presented the same pattern of response to the different strategies used in this study, which reinforces the need to look at optimizing cochlear implant clinical programming.


Assuntos
Percepção Auditiva/fisiologia , Surdez/cirurgia , Percepção da Fala/fisiologia , Criança , Pré-Escolar , Implante Coclear , Implantes Cocleares , Surdez/reabilitação , Feminino , Humanos , Masculino , Estudos Prospectivos , Processamento de Sinais Assistido por Computador , Testes de Discriminação da Fala
7.
Rev. CEFAC ; 15(5): 1181-1188, set.-out. 2013. tab
Artigo em Português | LILACS | ID: lil-694110

RESUMO

OBJETIVO: identificar o motivo da ausência no acompanhamento audiológico dos usuários de aparelhos de amplificação sonora individual do Sistema Único de Saúde e analisar o resultado da adaptação do dispositivo nesta população. MÉTODO: entrevista com 27 pacientes faltosos, realizando questões abertas sobre o motivo da ausência no atendimento e aplicação do Questionário Internacional de Aparelho de Amplificação Sonora Individual, para avaliação dos resultados pós-adaptação. A comparação dos resultados pós-adaptação dos pacientes faltosos foi realizada a partir da seleção aleatória de 30 questionários, de pacientes que compareceram no acompanhamento audiológico da Instituição, cadastrados em um banco de dados. Para análise dos resultados foi aplicada estatística descritiva e inferencial. RESULTADOS: a maioria dos faltosos (25,92%) refere não ter lembrado da data do retorno. Os resultados comparativos do questionário entre os grupos de faltosos e não faltosos evidenciam diferenças estatisticamente significantes em quase todos os domínios do questionário de auto-avaliação, exceto nos itens benefício, restrição da participação e qualidade de vida. CONCLUSÃO: dentre os motivos do não comparecimento ao serviço, destacam-se: esquecimento do atendimento, problemas de saúde e motivos de trabalho. Foi observado que os pacientes que não compareceram ao acompanhamento audiológico apresentam resultados pós-adaptação de aparelho de amplificação sonora individual aquém aos resultados dos pacientes que compareceram ao acompanhamento, de forma estatisticamente significante.


PURPOSE: to identify the reason for absence of the patients from the Unified Health System who use hearing aids at the audiology follow up and analyze the the device adaptation in this population. METHOD: 27 absent patients were interviewed with opened questions about their absence and the implementation of the International Outcome Inventory for Hearing Aids, a self-assessment questionnaire for post adaptation evaluation. Comparison of absent patients' post adaptation was performed from a random selection of 30 questionnaires from patients who attended the audiologic follow-up at the Institution (control group) who were registered in a database. Descriptive and inferential statistics (Mann-Whitney test - significance level of 5%) were applied for data analysis. RESULTS: the majority of absent patients (25.92%) say they didn't remember the return date for follow up. The questionnaire's comparative results between the absent and non-absent groups showed statistically significant differences in almost every area of self-assessment questionnaire, except on benefit items, participation restriction and quality of life CONCLUSION: among the reasons for not attending the service, we can highlight: forgetting the appointment, health problems and work reasons. It was observed that patients who did not attend the audiologic follow-up showed statistically significant post-adaptation results inferior when compared to the patients who attended the follow-up.

8.
Braz. j. otorhinolaryngol. (Impr.) ; 79(5): 629-635, Sep-Oct/2013. tab, graf
Artigo em Português | LILACS | ID: lil-688620

RESUMO

Aestratégia de processamento de sinal é um parâmetro que pode influenciar o desempenho auditivo do usuário de implante coclear e torna-se importante otimizar este parâmetro para proporcionar melhor percepção da fala, especialmente em situações de difícil escuta. OBJETIVO: Analisar os resultados individuais do desempenho auditivo de crianças usuárias de implante coclear, utilizando diferentes estratégias de processamento do sinal. MÉTODO: Estudo prospectivo com 11 crianças com deficiência auditiva pré-lingual e com habilidade auditiva de reconhecimento em conjunto aberto. Foi realizada a avaliação em três momentos, de acordo com a estratégia de fala utilizada (HiRes 120 e HiRes). Os participantes foram submetidos à audiometria em campo livre e avaliação da percepção da fala (silêncio e ruído). RESULTADOS: No silêncio, as crianças S1, S4, S5, S7 apresentaram melhor desempenho com a estratégia HiRes 120 e as crianças S2, S9, S11 apresentaram melhor desempenho com a estratégia HiRes. No ruído, também foi possível observar que algumas crianças obtiveram melhor desempenho utilizando a estratégia HiRes 120 e outras com a HiRes. CONCLUSÃO: Nem todas as crianças avaliadas apresentaram o mesmo padrão de resposta com as diferentes estratégias utilizadas neste estudo, o que reforça a necessidade de olhar clínico na otimização da programação do implante coclear. .


The signal processing strategy is a parameter that may influence the auditory performance of cochlear implant and is important to optimize this parameter to provide better speech perception, especially in difficult listening situations. OBJECTIVE: To evaluate the individual's auditory performance using two different signal processing strategy. METHOD: Prospective study with 11 prelingually deafened children with open-set speech recognition. A within-subjects design was used to compare performance with standard HiRes and HiRes 120 in three different moments. During test sessions, subject's performance was evaluated by warble-tone sound-field thresholds, speech perception evaluation, in quiet and in noise. RESULTS: In the silence, children S1, S4, S5, S7 showed better performance with the HiRes 120 strategy and children S2, S9, S11 showed better performance with the HiRes strategy. In the noise was also observed that some children performed better using the HiRes 120 strategy and other with HiRes. CONCLUSION: Not all children presented the same pattern of response to the different strategies used in this study, which reinforces the need to look at optimizing cochlear implant clinical programming. .


Assuntos
Criança , Pré-Escolar , Feminino , Humanos , Masculino , Percepção Auditiva/fisiologia , Surdez/cirurgia , Percepção da Fala/fisiologia , Implante Coclear , Implantes Cocleares , Surdez/reabilitação , Estudos Prospectivos , Processamento de Sinais Assistido por Computador , Testes de Discriminação da Fala
9.
Codas ; 25(6): 584-7, 2013.
Artigo em Inglês, Português | MEDLINE | ID: mdl-24626984

RESUMO

PURPOSE: To perform a systematic review of the literature on questionnaires to assess the benefits of using hearing aids in children. METHODS: A literature search was conducted in the data-bases Web of Science and Virtual Health Library (BIREME). The selection criteria included: title consistent with the purpose of this review; participants necessarily being children using hearing aids; and questionnaires to assess the benefits and satisfaction. RESULTS: More evidence was found in studies that used the scale Parent's Evaluation of Aural/Oral Performance of Children (PEACH), making it possibly the most consistent scale on the subjective evaluation of the use of amplification in children. CONCLUSION: There is a paucity of studies with this approach; however, the results showed the importance of researches in this area, which turns the subject into an important field of research.


Assuntos
Correção de Deficiência Auditiva , Auxiliares de Audição , Inquéritos e Questionários , Criança , Prática Clínica Baseada em Evidências , Transtornos da Audição/terapia , Humanos , Pais , Satisfação Pessoal
10.
Codas ; 25(1): 16-21, 2013.
Artigo em Inglês, Português | MEDLINE | ID: mdl-24408165

RESUMO

PURPOSE: To validate a monitoring questionnaire about hearing and language development applied by community health agents in the first year of life. METHODS: Seventy six community health agents, previously trained on infant hearing health, administered a questionnaire to the families of 304 children with ages from 0 to 1 year. The questionnaire contains questions regarding hearing and language development and, for all age groups, the question "Does your child hear well?" was presented. The validity of the questionnaire was assessed by analyzing false positive and false negative rates of the identified children. A double-blind study was conducted so that all children assessed by the questionnaire were submitted to hearing evaluation performed by audiologists. RESULTS: Four children (1.32%) were diagnosed with sensorineural hearing loss (two unilateral), and 69 (22.7%) with conductive hearing loss. The monitoring questionnaire showed specificity of 96% and sensitivity of 67%, with a false-negative rate of 33% for not identifying the unilateral hearing loss, and a false-positive rate of 4%. CONCLUSION: The questionnaire used has shown to be feasible and relevant to actions of the community health agents of the Family Health Strategy program, with high specificity and moderate sensitivity. The use of the validated instrument should be considered to complement Newborn Hearing Screening Programs, in order to identify late onset or acquired hearing loss.


Assuntos
Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Neurossensorial/diagnóstico , Testes Auditivos/métodos , Inquéritos e Questionários , Método Duplo-Cego , Reações Falso-Negativas , Reações Falso-Positivas , Saúde da Família , Humanos , Lactente , Recém-Nascido , Desenvolvimento da Linguagem , Programas Nacionais de Saúde , Sensibilidade e Especificidade
11.
CoDAS ; 25(1): 16-21, 2013. ilus, tab
Artigo em Português | LILACS | ID: lil-672152

RESUMO

OBJETIVO: Validar um questionário de monitoramento do desenvolvimento da função auditiva e de linguagem, aplicado por agentes comunitários de saúde no primeiro ano de vida. MÉTODOS: Setenta e seis agentes comunitários de saúde, capacitados previamente em saúde auditiva infantil, aplicaram o questionário às famílias de 304 crianças de 0 a 1 ano de idade. O questionário constitui-se de questões sobre o desenvolvimento da função auditiva e da linguagem, sendo que para todas as faixas etárias possui a questão "Seu filho ouve bem?". A validade do questionário foi averiguada por meio da análise das taxas de falso-positivo e falso-negativo das crianças investigadas por ele. Para tanto, foi utilizado um estudo duplo-cego em que todas as crianças investigadas pelo questionário foram submetidas à avaliação audiológica realizada por fonoaudiólogos. RESULTADOS: Foram diagnosticadas quatro crianças (1,32%) com perda auditiva sensorioneural, sendo duas unilaterais e 69 crianças (22,7%) com perda auditiva condutiva. O questionário de acompanhamento demonstrou especificidade de 96% e sensibilidade de 67%, com taxa de falso-negativo de 33%, por não identificar as perdas auditivas unilaterais, e falso-positivo de 4%. CONCLUSÃO: A utilização do questionário proposto mostrou-se viável e pertinente às ações desenvolvidas pelos agentes comunitários de saúde da Estratégia de Saúde da Família, demonstrando alta especificidade e moderada sensibilidade. A utilização do instrumento validado deve ser considerada como forma complementar aos Programas de Triagem Auditiva Neonatal, a fim de identificar as alterações auditivas de caráter adquirido ou de início tardio.


PURPOSE: To validate a monitoring questionnaire about hearing and language development applied by community health agents in the first year of life. METHODS: Seventy six community health agents, previously trained on infant hearing health, administered a questionnaire to the families of 304 children with ages from 0 to 1 year. The questionnaire contains questions regarding hearing and language development and, for all age groups, the question "Does your child hear well?" was presented. The validity of the questionnaire was assessed by analyzing false positive and false negative rates of the identified children. A double-blind study was conducted so that all children assessed by the questionnaire were submitted to hearing evaluation performed by audiologists. RESULTS: Four children (1.32%) were diagnosed with sensorineural hearing loss (two unilateral), and 69 (22.7%) with conductive hearing loss. The monitoring questionnaire showed specificity of 96% and sensitivity of 67%, with a false-negative rate of 33% for not identifying the unilateral hearing loss, and a false-positive rate of 4%. CONCLUSION: The questionnaire used has shown to be feasible and relevant to actions of the community health agents of the Family Health Strategy program, with high specificity and moderate sensitivity. The use of the validated instrument should be considered to complement Newborn Hearing Screening Programs, in order to identify late onset or acquired hearing loss.


Assuntos
Humanos , Lactente , Recém-Nascido , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Neurossensorial/diagnóstico , Testes Auditivos/métodos , Inquéritos e Questionários , Método Duplo-Cego , Reações Falso-Negativas , Reações Falso-Positivas , Saúde da Família , Desenvolvimento da Linguagem , Programas Nacionais de Saúde , Sensibilidade e Especificidade
12.
Rev. Soc. Bras. Fonoaudiol ; 17(4): 476-481, dez. 2012. tab
Artigo em Português | LILACS | ID: lil-661056

RESUMO

O implante coclear (IC) tem sido indicado para crianças deficientes auditivas de grau severo e/ou profundo que não tem benefício com o aparelho de amplificação sonora individual (AASI), e que apresentem família adequada e motivada para o uso do dispositivo, bem como condições adequadas de reabilitação na cidade de origem. Atualmente, a procura pelo IC também ocorre por pais surdos, fluentes na Língua Brasileira de Sinais (LIBRAS), que recorrem a este tratamento para oferecer outra realidade para seus filhos. O ambiente destas crianças é bilíngue, dado pela LIBRAS dos pais e pela linguagem oral dos familiares próximos, do fonoaudiólogo e da escola. Neste sentido, o presente estudo visou acompanhar quatro crianças deficientes auditivas implantadas, sendo duas crianças filhas de pais deficientes auditivos fluentes na LIBRAS (expostas a ambiente bilíngue) e duas crianças filhas de pais sem alterações auditivas (expostas a ambiente oral). Para tanto, as habilidades de audição e de aquisição da linguagem oral foram comparadas nas quatro crianças implantadas. Foi possível observar que as quatro crianças apresentaram habilidades auditivas e de linguagem semelhantes ao longo do primeiro ano de uso do IC. Contudo, a partir disto, as crianças inseridas em ambiente bilíngue apresentaram melhor desempenho auditivo e linguístico, comparado ao desenvolvimento das outras crianças. As crianças inseridas em ambiente bilíngue podem se beneficiar do IC, desenvolvendo habilidades auditivas e de linguagem similares às das crianças inseridas em ambiente oral. Ressalta-se que os benefícios do dispositivo são obtidos a partir de aspectos multifatoriais, e estudos mais aprofundados são necessários.


The cochlear implant (CI) has been indicated for children with severe and/or profound bilateral hearing loss who do not benefit from hearing aids and have adequate and motivated family for the use of the device, as well as adequate rehabilitation conditions at their hometowns. Currently, the demand for CI also occurs by deaf parents, fluent in Brazilian Sign Language (LIBRAS), who resort to this treatment to offer their children another reality. The environment of these children is bilingual, with exposition to LIBRAS through their parents and to oral language through close relatives, audiologist/speech-language pathologist, and the school. In this sense, the present study aimed to follow-up four implanted deaf children - two with deaf parents fluent in LIBRAS (exposed to a bilingual environment), and two with hearing parents (exposed to oral environment). For this purpose, abilities of hearing and oral language development were compared in these children with CI. It was observed that all four children in this study presented similar language development and auditory skills throughout the first year of CI use. However, after this period, children inserted into a bilingual environment had better auditory and linguistic performance when compared to the other children. Children in bilingual environments can benefit from the CI, developing auditory skills and oral language similarly to children inserted into an oral environment. It is emphasized that the benefits of the device is dependent on several factors, and further studies are needed.

13.
Braz J Otorhinolaryngol ; 78(3): 129-33, 2012 Jun.
Artigo em Inglês, Português | MEDLINE | ID: mdl-22714858

RESUMO

UNLABELLED: Despite technological advances employed in signal processing strategies, one of the remaining obstacles are spectral gap details on the information transmitted. Considering its importance in speech perception, researchers have investigated mechanisms to optimize spectral details through virtual spectral channels. The clinical application of this technique resulted in a new approach to signal processing - the HiRes 120. OBJECTIVE: To assess the auditory performance of cochlear implant users with the HiRes 120 strategy. METHODOLOGY: The literature review was conducted in an electronic database, with standard bibliographic search in the year 2011, using specific keywords. In order to select and evaluate the scientific studies found in the search, we setup search containing the following aspects: type of study, subjects, intervention used and evaluation of the results. CONCLUSION: Scientific evidence points to an improvement in hearing performance in noisy environments with the HiRes 120 strategy, but this does not occur in quiet situations. The optimization of speech perception with this strategy is closely related to the cochlear implant user's age, to the time of sensory deprivation and the acclimatization time required to use the strategy's spectral information.


Assuntos
Estimulação Acústica/métodos , Implante Coclear/reabilitação , Implantes Cocleares , Surdez/reabilitação , Percepção da Fala/fisiologia , Surdez/cirurgia , Humanos
14.
Braz. j. otorhinolaryngol. (Impr.) ; 78(3): 129-133, maio-jun. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-638593

RESUMO

Apesar dos avanços tecnológicos empregados nas estratégias de processamento do sinal, um dos obstáculos ainda existentes são as lacunas de detalhes espectrais na informação elétrica transmitida. Considerando a sua importância na percepção da fala, pesquisadores investigaram mecanismos para otimizar o detalhamento espectral, por meio dos canais espectrais virtuais. A aplicação clínica desta técnica resultou em uma nova estratégia de processamento de sinal - a HiRes 120. OBJETIVO: Avaliar o desempenho auditivo de usuários de Implante Coclear com a HiRes 120. METODOLOGIA: Levantamento bibliográfico conduzido em base eletrônica de dados, com busca padronizada até o ano de 2011, utilizando-se palavras-chave específicas. Para a seleção e avaliação dos estudos científicos levantados na busca, foram estabelecidos critérios, contemplando os aspectos: tipo de estudo, participantes, intervenção adotada e avaliação dos resultados. CONCLUSÃO: As evidências científicas apontam uma melhora do desempenho auditivo nas situações de ruído com a estratégia HiRes 120, mas tal fato não ocorre nas situações de silêncio. A otimização da percepção da fala com o uso da estratégia está intimamente relacionada com a idade do usuário de implante coclear, com o tempo de privação sensorial e o tempo de aclimatização necessário para o aproveitamento das informações espectrais da estratégia.


Despite technological advances employed in signal processing strategies, one of the remaining obstacles are spectral gap details on the information transmitted. Considering its importance in speech perception, researchers have investigated mechanisms to optimize spectral details through virtual spectral channels. The clinical application of this technique resulted in a new approach to signal processing - the HiRes 120. OBJECTIVE: To assess the auditory performance of cochlear implant users with the HiRes 120 strategy. METHODOLOGY: The literature review was conducted in an electronic database, with standard bibliographic search in the year 2011, using specific keywords. In order to select and evaluate the scientific studies found in the search, we setup search containing the following aspects: type of study, subjects, intervention used and evaluation of the results. CONCLUSION: Scientific evidence points to an improvement in hearing performance in noisy environments with the HiRes 120 strategy, but this does not occur in quiet situations. The optimization of speech perception with this strategy is closely related to the cochlear implant user's age, to the time of sensory deprivation and the acclimatization time required to use the strategy's spectral information.


Assuntos
Humanos , Estimulação Acústica/métodos , Implantes Cocleares , Implante Coclear/reabilitação , Surdez/reabilitação , Percepção da Fala/fisiologia , Surdez/cirurgia
15.
J Soc Bras Fonoaudiol ; 24(4): 390-4, 2012.
Artigo em Inglês, Português | MEDLINE | ID: mdl-23306692

RESUMO

The cochlear implant (CI) represents the most important advance in the treatment of individuals with severe to profound bilateral hearing loss who do not benefit from hearing aids. Children who receive the CI during the critical period of neuroplasticity of the auditory system, when combined with speech therapy, have the chance to develop the auditory and linguistic skills similarly to their normal hearing peers. Two cases of implanted children are presented in this study, and one of them was not enrolled in a formal aurioral therapeutic program since the implantation surgery. At the moment of language and auditory assessment, the children were 2 years and 5 months old, and the CI had been used for 11 months. According to the results presented, it was observed that the child enrolled in rehabilitation program had better auditory and language performance when compared to the other child. Despite the remarkable benefits that the CI provides to children with hearing impairment, the device itself only provides the child with the audibility of environmental sounds and speech signal. For the auditory and language development to happen, it is necessary, among other factors, a speech-language intervention, with partnership between professionals and parents.


Assuntos
Implantes Cocleares , Perda Auditiva Neurossensorial/reabilitação , Transtornos do Desenvolvimento da Linguagem/terapia , Desenvolvimento da Linguagem , Medida da Produção da Fala , Pré-Escolar , Implante Coclear , Feminino , Perda Auditiva Neurossensorial/cirurgia , Humanos , Resultado do Tratamento
16.
J. Soc. Bras. Fonoaudiol ; 24(4): 390-394, 2012. tab
Artigo em Português | LILACS | ID: lil-660599

RESUMO

O implante coclear (IC) representa o mais importante avanço no tratamento de deficientes auditivos de grau severo e/ou profundo bilateral que não apresentam aproveitamento com o aparelho de amplificação sonora individual. A realização do IC no período crítico da neuroplasticidade do sistema auditivo possibilita que o desenvolvimento auditivo e linguístico de crianças implantadas precocemente sejam semelhantes ao desenvolvimento destas habilidades em crianças ouvintes, quando associadas à terapia fonoaudiológica. Os casos a serem apresentados referem-se a duas crianças usuárias de IC, sendo que uma delas não estava inserida em programa terapêutico com abordagem aurioral desde a realização da cirurgia do dispositivo. No momento da aplicação dos protocolos para avaliação das habilidades auditivas e de linguagem, as crianças estavam com 2 anos e 5 meses de idade e 11 meses de uso do IC. De acordo com os resultados apresentados pelos casos estudados foi possível observar que a criança inserida em programa terapêutico apresentou melhor desempenho auditivo e linguístico, comparada ao desenvolvimento da outra criança. Apesar dos notáveis benefícios que o IC proporciona nas crianças deficientes auditivas, o dispositivo por si só proporciona à criança audibilidade aos sons ambientais e de fala. Para que o desenvolvimento auditivo e linguístico aconteça torna-se necessário, dentre outros fatores, a realização da terapia fonoaudiológica, com parceria entre profissionais e pais.


The cochlear implant (CI) represents the most important advance in the treatment of individuals with severe to profound bilateral hearing loss who do not benefit from hearing aids. Children who receive the CI during the critical period of neuroplasticity of the auditory system, when combined with speech therapy, have the chance to develop the auditory and linguistic skills similarly to their normal hearing peers. Two cases of implanted children are presented in this study, and one of them was not enrolled in a formal aurioral therapeutic program since the implantation surgery. At the moment of language and auditory assessment, the children were 2 years and 5 months old, and the CI had been used for 11 months. According to the results presented, it was observed that the child enrolled in rehabilitation program had better auditory and language performance when compared to the other child. Despite the remarkable benefits that the CI provides to children with hearing impairment, the device itself only provides the child with the audibility of environmental sounds and speech signal. For the auditory and language development to happen, it is necessary, among other factors, a speech-language intervention, with partnership between professionals and parents.


Assuntos
Pré-Escolar , Feminino , Humanos , Implantes Cocleares , Perda Auditiva Neurossensorial/reabilitação , Desenvolvimento da Linguagem , Transtornos do Desenvolvimento da Linguagem/terapia , Medida da Produção da Fala , Implante Coclear , Perda Auditiva Neurossensorial/cirurgia , Resultado do Tratamento
17.
São Paulo; s.n; 2012. [122] p. tab, graf, ilus.
Tese em Português | LILACS | ID: lil-664740

RESUMO

A melhora na percepção da fala dos usuários de implante coclear (IC) ao longo do tempo está relacionada, entre outros fatores, ao avanço tecnológico das estratégias de processamento do sinal. Deste modo, o objetivo deste trabalho foi avaliar o desempenho de percepção da fala em crianças usuárias de IC, utilizando duas diferentes estratégias de processamento do sinal do sistema HiResolution da Advanced Bionics. Para tanto, participaram deste estudo 11 crianças com deficiência auditiva pré-lingual, usuárias do componente interno HiRes 90K e processador de fala modelo platinum, e que apresentavam habilidade auditiva de reconhecimento em conjunto aberto. Foi realizada a avaliação intra-sujeito em três momentos, de acordo com a estratégia de fala utilizada. O desempenho da linha de base foi avaliado com a estratégia HiResolution 120 (HiRes 120) e posteriormente, foi realizada a conversão da estratégia para a HiResolution (HiRes). Após três meses de uso da estratégia HiRes, os participantes foram avaliados e realizada a conversão da estratégia para a HiRes 120. Após três meses de uso da HiRes 120, os participantes foram reavaliados. Em todas as avaliações, os participantes foram submetidos à pesquisa dos limiares audiométricos em campo livre, avaliação da percepção da fala por meio do teste Hearing in Noise (HINT), no silêncio e na presença de ruído competitivo e, avaliação dos benefícios proporcionados pelo uso do IC em situações cotidianas, por meio do questionário Parents' Evaluation of Aural/oral Performance of Children (PEACH). Os resultados demonstraram que não houve diferença dos limiares audiométricos em campo livre, do desempenho auditivo no silêncio e do benefício do IC em situações de vida diária, em função da estratégia de processamento de sinal utilizada. Houve tendência de melhor desempenho auditivo na situação de ruído com o uso da estratégia de processamento de sinal HiRes 120, embora, tal resultado não tenha sido estatisticamente significante. ...


Improvements in speech perception with cochlear implant (CI) over the years is related, among others factors, to the technological advance of the sound processing strategy. The purpose of the present study was to investigate speech perception performance in CI children, with two different Advanced Bionics sound processing strategy. Subjects were 11 prelingually deafened children implanted with the HiRes 90K cochlear implant and used a bodyworn platinum sound processor. All subjects showed evidence of open-set speech recognition. A within-subjects design was used to compare performance with standard HiRes and HiRes 120. Baseline performance was assessed with HiResolution 120 (HiRes 120). Subjects then were fitted with HiResolution (HiRes) and returned for re-evaluation after three months of use. After three months of HiRes experience, subjects were refitted with HiRes 120 and returned three months later for reassessment. During test sessions, subject's performance was evaluated by warble-tone sound-field thresholds, the Brazilian Hearing in Noise test (HINT) in quiet and in noise and Parents' Evaluation of Aural/oral Performance of Children questionnaire (PEACH). The detection thresholds, the speech perception in quiet and the CI benefit in daily life were similar for both sound processing strategy. There was a trend toward better hearing performance in noise with HiRes 120, although this result was not statistically significant. This trend indicates that more precise spectral representation of the acoustic signal provided by the HiRes 120 can result in an improvement in the speech perception in noise by CI children. However, this characteristic did not influence the auditory performance in quiet. It reinforces the importance of clinical observation and speech perception in noise assessment in the sound processing strategy selection, in order to optimize the auditory performance of CI users...


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Implante Coclear , Perda Auditiva , Avaliação de Resultados em Cuidados de Saúde , Percepção da Fala
18.
Rev. CEFAC ; 13(4): 692-697, jul.-ago. 2011. tab
Artigo em Português | LILACS | ID: lil-598572

RESUMO

OBJETIVO: avaliar a videoconferência como ferramenta instrucional na capacitação dos agentes comunitários de saúde, em saúde auditiva infantil, sob a perspectiva destes profissionais. METODOLOGIA: a casuística foi composta por 50 agentes comunitários de saúde, divididos aleatoriamente em dois grupos de acordo com a metodologia de ensino: 31 profissionais participaram da capacitação de forma presencial e 19 por meio de videoconferência. A atividade ocorreu em um encontro de oito horas, por meio de aulas expositivas e utilizando material didático adaptado e validado para o português proposto pela Organização Mundial da Saúde de forma simultânea para ambos os grupos. A avaliação da videoconferência como ferramenta instrucional foi realizada por meio de questionário elaborado para o presente estudo. RESULTADOS: a avaliação da videoconferência foi muito semelhante em ambos os grupos, sendo que a ferramenta de ensino foi considerada como de fácil entendimento e permitindo a interação com o ministrante. CONCLUSÃO: a videoconferência foi uma ferramenta válida e aceita pelos profissionais estudados para ser utilizada em programas de capacitação em saúde auditiva infantil.


PURPOSE: to check the opinion from community health agents about the use of videoconference as instructional tool in children hearing health program training. METHODS: the group was made up by 50 community health agents divided randomly in two groups, with the following sample: 31 community health agents by face-to-face instruction and 19, by videoconference. The training was provided in eight hours, through classes and a textbook translated and adapted into the Brazilian Portuguese language proposed by World Health Organization, in both groups, simultaneously. In order to investigate the opinion about the use of videoconference as instructional tool in training program, a questionnaire was done and applied, in both group, after the course. RESULTS: the videoconference quality evaluation , compared by face-to-face instruction, in the opinion of health care professionals was similar, and was considered easy and interactive. CONCLUSION: the videoconference was a valid and accepted learning tool to be adopted in training programs for community health agents.

19.
Rev. Soc. Bras. Fonoaudiol ; 16(3): 252-259, 2011. graf, tab
Artigo em Português | LILACS | ID: lil-598638

RESUMO

OBJETIVO: Realizar o levantamento do quantitativo dos procedimentos relacionados à adaptação de aparelho de amplificação sonora individual (AASI) incluídos na Tabela do Sistema Único de Saúde (Tabela SUS). MÉTODOS: Os dados sobre os procedimentos relacionados à adaptação de AASI incluídos na Tabela SUS foram levantados no site www.datasus.gov.br. Após o levantamento desses dados, foi realizada a organização e a análise descritiva da produção dos atendimentos ambulatoriais registrados pelos serviços de saúde auditiva do Brasil, durante o período de novembro de 2004 a julho de 2010. Os dados foram analisados estatisticamente. RESULTADOS: Quanto aos procedimentos relacionados à dispensação de AASI no território nacional no âmbito da saúde auditiva, em 2006, a terapia fonoaudiológica ultrapassou o quantitativo obtido pela adaptação de AASI e, o acompanhamento fonoaudiológico, por sua vez, foi pouco realizado no país. Os AASI com tecnologias B e C vem sendo mais adaptados do que os AASI de tecnologia A e a realização de medida com microfone sonda ou acoplador de 2cc na adaptação dos AASI é pouco realizada em comparação ao ganho funcional. CONCLUSÃO: Houve grandes avanços na atenção ao deficiente auditivo no país, mas é necessário aprimorar o acompanhamento dos usuários de AASI, e revisar procedimentos como medidas com microfone sonda e tecnologias dos AASI.


PURPOSE: To quantity the procedures related to hearing aid fitting included in Hearing Health Care National Policy (Tabela SUS). METHODS: Data about fitting procedures included in Tabela SUS were gathered in the website www.datasus.gov.br. After data collection, it was conducted the organization and descriptive analysis of the production of ambulatory consults registered by hearing health services in Brazil, during the period from November 2004 to July 2010. Data were statistically analyzed. RESULTS: Regarding procedures related to dispensing hearing aids in national territory, in 2006, speech-language therapy exceeded the amount obtained by hearing aid fitting, and audiological follow-up was little frequent. Hearing aids with technologies B and C have been adapted more than hearing aids with technology A, and the use of measures with a real-ear measurement or 2cc coupler in the adaptation of hearing aids is uncommon, in comparison to functional gain measures. CONCLUSION: There has been great progresses in the area of hearing impaired attention in the country, but it is necessary to improve the audiological follow-up to hearing aid users, and to review procedures such as the real-ear measurement and technologies of hearing aids.


Assuntos
Humanos , Audiologia , Auxiliares de Audição , Perda Auditiva , Política de Saúde , Sistema Único de Saúde
20.
Rev. Soc. Bras. Fonoaudiol ; 16(1): 49-53, 2011. tab
Artigo em Português | LILACS | ID: lil-580413

RESUMO

OBJETIVO: Avaliar a adesão dos pais para a realização dos procedimentos auditivos em um Programa de Saúde Auditiva Infantil, desenvolvido na comunidade. MÉTODOS: Foi realizada uma análise comparativa das informações sobre o comparecimento nos atendimentos de dois Programas de Saúde Auditiva Infantil, um vinculado a um hospital público e outro realizado junto à Estratégia Saúde da Família (ESF). A casuística foi formada por 362 crianças, nascidas entre o período de fevereiro a março de 2007 no Hospital em que é realizada a triagem auditiva, e que foram agendadas para participar do Programa junto a ESF. RESULTADOS: Das 362 crianças que nasceram neste hospital e que foram encaminhadas para realização da avaliação audiológica na unidade básica de saúde, 147 compareceram ao atendimento, representando 40,61 por cento de adesão das famílias no projeto desenvolvido na comunidade. Dos casos com resultado de triagem auditiva sugestivo de ausência de alteração auditiva, somente 39,80 por cento aderiram ao Programa realizado junto ao ESF. Dos casos que não completaram alguma etapa do processo de identificação na maternidade, 32 (55,18 por cento) famílias não aderiram a nenhum dos Programas de Saúde Auditiva existentes, ficando sem esclarecimento sobre a audição do filho. CONCLUSÃO: O comparecimento das famílias nas UBS foi inferior à metade das famílias que foram convidadas a levar os filhos para a avaliação audiológica, independentemente de se a criança havia sido submetida ao processo de identificação da deficiência auditiva na maternidade pública da cidade.


PURPOSE: To evaluate the commitment of parents for carrying out the hearing procedures of a Children's Hearing Health Program at their community. METHODS: It was carried out a comparative analysis of the information regarding parents' attendance at two Children's Hearing Health Programs, one developed at a public hospital and the other carried out along with the Family Health Program (FHP). The sample comprised 362 children born between February and March 2007 at the hospital in which the hearing screening was performed, and who were enrolled in the FHP. RESULTS: From the 362 children who had been born at the hospital and referred for hearing evaluation at the basic health unit of the same community, 147 attended the evaluation, representing 40.61 percent of commitment to the project developed there. Only 39.80 percent of the families whose children's screening suggested no hearing alterations committed the program carried out along with the FHP. Thirty-two families (55.18 percent) did not participate in any of the existing hearing health programs, therefore remaining unaware of their child's hearing condition. CONCLUSION: The attendance of the families at the basic health unit was less than half of the families who had been invited to take the children for hearing evaluation, regardless if the child had been submitted to the process of identification of hearing loss at the public hospital.


Assuntos
Humanos , Saúde da Família , Planos e Programas de Saúde , Audição , Perda Auditiva , Triagem Neonatal , Sistema Único de Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...